日本道 高清一区二区三区,最近中文字幕完整版HD,欧美人妻精品一区二区三,日本久久精品一区二区三区

產(chǎn)品列表PRODUCTS LIST

聯(lián)系信息

  • 電話:
    029-88231631
  • 傳真:
    029-88231651
首頁 > 技術與支持 > ARCH電源應用資料
ARCH電源應用資料
點擊次數(shù):3206 更新時間:2009-03-09

[ Application Note ]   

 

  AC-DC Application Note  
 
          AC Input Line Connection :
  The pin of AC line (L), ac neutral (N),the third wire safety ground (FG) should be retained from the AC power outlet to the power supply input terminals without accidental interchange. (Figure 1.1)
  (Figure 1.1)
  The FG pin should be connected to the equipment where power supply is placed as thickershorter to protect electric shock or noise interference. (Figure 1.2)
  (Figure 1.2)
 
 
          Fuse :
  To add a fuse at the input terminals of the power supply to provide safetyprotection. We suggest using a 1. slow blow fuse for our AC-DC Converters including AHC, APC, ATC, ANCASC series. (Figure 2.1)
  (Figure 2.1)
 
 
          Seriesparallel operation :
  I. Series operation
Most power converters can be operated in series if they have overload limitation by either constant current or constant power circuits. To protect each output from the reverse voltage applied by the other unit in the event of load short circuits, reverse biased diodes are used as shown in Figure 3.1
  (Figure 3.1)
  II. Parallel operation
This is only recommended with power converters specifically designed for parallel connection. In the parallel redundant scheme illustrated in Figure 3.2 one of the power converters could be replaced by a battery followed by a DC-DC converter to provide a no-break power system in the event of main supply failure.
  (Figure 3.2)
 
 
          Reduce the output ripplenoise :
  Please be aware the length of screw should not be longer than 3 mm while you mounting/ adopting our power supply on your end application, in case screw break through Mylar or PCB Board result in short circuit.
  (Figure 4.1)
 
 
          Screws for Switching Power Supply (AQS & AQF Series) :
  Please be aware the length of screw should not be longer than 3 mm while you mounting/ adopting our power supply on your end application, in case screw break through Mylar or PCB Board result in short circuit.
 
     
  DC-DC Application Note  
 
          Connection for standard use :
  Cin: External capacitor on the input side
Co: External capacitor on the output side
 
 
 
          Reverse input voltage protection :
  Avoid the reverse input voltage because it will damage the power supply. Installing an external diode can protect the converter from the reverse input voltage.
 
 
 
          Seriesparallel operation :
  I. Series operation
Most power converters can be operated in series if they have overload limitation by either constant current or constant power circuits. To protect each output from the reverse voltage applied by the other unit in the event of load short circuits, reverse biased diodes are used as shown in Figure 3.1
  (Figure 3.1)
  II. Parallel operation
This is only recommended with power converters specifically designed for parallel connection. In the parallel redundant scheme illustrated in Figure 3.2 one of the power converters could be replaced by a battery followed by a DC-DC converter to provide a no-break power system in the event of main supply failure.
  (Figure 3.2)
 
 
          Remote On/ Off Control Pin :
  Positive logic remote on/ off turns the module on during a logic high voltage on the remote on/ off pin,off during a logic voltage low. In order to turn module on or off, the use must supply a switch to control the voltage between the on / off terminalthe –Vin terminal.
 
  AC-DC Application Note: Download AC-DC Application Note PDF File                           DC-DC Application Note: Download DC-DC Application Note PDF File

邯郸市| 江安县| 会理县| 宁乡县| 黎川县| 海淀区| 化德县| 温泉县| 柳林县| 桃江县| 龙州县| 曲阳县| 丰城市| 越西县| 噶尔县| 定安县| 卢氏县| 淮安市| 乌兰浩特市| 朝阳县| 文水县| 旬邑县| 招远市| 平谷区| 金门县| 中阳县| 封开县| 沈阳市| 桑日县| 长海县| 宿州市| 天全县| 临西县| 珲春市| 江山市| 花垣县| 苍山县| 肥城市| 兰溪市| 当涂县| 铁岭市|